Practical Considerations in Trace Element Analysis of Bone Using Portable X-ray Fluorescence

dc.contributor.authorByrnes, Jennifer
dc.contributor.authorBush, Peter J.
dc.date.accessioned2017-03-30T01:25:55Z
dc.date.available2017-03-30T01:25:55Z
dc.date.issued2016-07
dc.description.abstractForensic anthropologists are more often turning to nondestructive methods to assist with skeletal analyses, specifically for trace elemental analyses. Portable XRF (pXRF) instruments are versatile and are able to be used in diverse settings or for specimens of a shape and size that cannot be accommodated by laboratory-based instruments. Use of XRF requires knowledge of analysis parameters such as X-ray penetration and exit depth. Analysis depth was determined by examining pure elements through known thicknesses of equine bone slices. Correlation between the element's X-ray emission energy and the depth of reading was observed. Bone surfaces from a small unknown historic cemetery were analyzed before and after sanding of the periosteal surface to observe possible changes in XRF readings based on potential diagenesis. Results validate the pXRF device as a powerful and convenient instrument for nondestructive analysis, while highlighting limitations and considerations for the analysis of osseous materials.
dc.format.extent5 pages
dc.identifier.doi10.1111/1556-4029.13103
dc.identifier.urihttp://hdl.handle.net/10790/3000
dc.language.isoen-US
dc.publisherWiley
dc.relation.urihttps://doi.org/10.1111/1556-4029.13103
dc.rightsThis is the peer reviewed version of the following article: Byrnes, J. F. and Bush, P. J. (2016), Practical Considerations in Trace Element Analysis of Bone by Portable X-ray Fluorescence. J Forensic Sci, 61: 1041–1045. doi:10.1111/1556-4029.13103, which has been published in final form at https://doi.org/10.1111/1556-4029.13103. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archiving.
dc.subject.lcshForensic anthropology
dc.subject.lcshForensic sciences
dc.subject.lcshDiagenesis
dc.titlePractical Considerations in Trace Element Analysis of Bone Using Portable X-ray Fluorescence
dc.typeArticle
dc.type.dcmiText

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
byrnes.j-2016-0001.pdf
Size:
264.96 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections